Embryo transfer is the core technology of livestock genetic improvement, and standardized controlled-rate freezing directly determines post-thaw embryo survival and pregnancy rate. Many general semen freezers cannot meet embryos’ strict cryogenic requirements: vertical design causes embryo sedimentation, manual ice seeding leads to unstable crystallization, uneven chamber temperature results in inconsistent freezing results, and external computer control brings complicated operation.


Our embryo-specialized programmable cooling system solves all pain points of traditional embryo freezers. Built with independent integrated control, horizontal placing structure, 360° uniform air circulation, and automatic ice seeding function, it fully matches the IETS standard slow freezing protocol for bovine, swine, goat, sheep, and deer embryos.

Embryo-dedicated programmable cooling system with auto-seeding & horizontal straw rack for livestock embryo slow freezing

1. 16 Exclusive Core Advantages of Our Embryo Programmable Cooler

  • Integrated automatic control system, no external PC required; independent touch screen completes all programming & operation.

  • Unlimited program storage capacity; new protocols can be edited and saved within 3 seconds, supporting thousands of customized cooling curves for different species & embryo stages.

  • No self-pressurized liquid nitrogen tank required; an ordinary atmospheric LN2 tank is available, greatly reducing lab equipment investment cost.

  • Horizontal placement design for embryo straw racks eliminates embryo sinking & cell damage caused by vertical stacking.

  • 360° surrounding air vents inside the freezing chamber, uniform temperature across every zone; all embryo straws get identical cooling conditions for consistent post-thaw viability.

  • Ultra-low power consumption: only 150W, suitable for small embryo labs with limited power supply.

  • Wide adjustable temperature range: +40°C ~ -160°C, covers all pre-equilibration, seeding and deep freezing stages for embryos.

  • Fully customizable temperature, cooling rate & holding time, freely match bovine, porcine, caprine and ovine embryo protocols.

  • Built-in automatic ice seeding system, no manual seeding operation; avoids human error and unstable crystal formation.

  • Specially optimized algorithm for embryo slow freezing, exclusive for livestock embryo straw cryopreservation.

  • Real-time full temperature curve recording, automatically stored inside the device, exportable for lab quality inspection & export certification.

  • Complete cycle completion alarm reminder, technicians do not need to monitor the whole freezing process.

  • Automatic constant temperature hold after program ends; even if you cannot transfer straws into LN2 tank immediately, embryos are protected from temperature shock damage.

  • Large HD touchscreen panel, clear data display, intuitive parameter editing interface.

  • One-touch start & stop function, simple operation for new lab staff without complex training.

  • Upgraded stable control hardware, ultra-low failure rate, long service life for continuous daily lab use.


2. Standard Complete Livestock Embryo Cryopreservation Workflow (Industry IETS Official Standard)

Pre-Freezing Preparation Steps

  1. Recover embryos in holding medium at 37°C, screen qualified blastocysts/morulae under a thermostatic microscope.

  2. Gradually equilibrate embryos in cryoprotectant (1.5M ethylene glycol) for 10 minutes at room temperature.

  3. Load embryos into standard 0.25ml embryo straws, seal and label unique ID, breed & collection date.

  4. Preheat the programmable cooling system, recall the matched embryo freezing program on the touch screen.

  5. Place straw racks horizontally into the freezing chamber, and close the insulated door tightly.

Automatic Program Running Stage (Standard Cooling Curve Attached Below)

  1. The machine automatically cools to seeding temperature and executes built-in auto ice seeding without manual operation.

  2. Hold stable temperature for sufficient dehydration time, then cool down at a fixed slow rate to the deep freezing target.

  3. After reaching the final temperature, the machine sends an audio alarm to remind technicians.

  4. The device automatically maintains a constant low temperature to prevent embryo damage during delayed transfer.

Post-Freezing Operation

  1. Take the straw racks out quickly after the alarm, transfer the straws into the liquid nitrogen tank for long-term preservation.

  2. Export recorded temperature curve data for lab-quality archives.

  3. Randomly thaw partial straws at a 37°C water bath to test post-thaw embryo survival rate under a heated microscope.


3. Universal Standard Embryo Slow Freezing Cooling Curve (Widely Adopted by Global Embryo Labs)

This is the mainstream IETS standard slow-freezing protocol for bovine, sheep, and goat embryos, fully editable & pre-stored in our programmable cooling system:

  1. Initial stage: Cool from room temperature (20°C) down to -7°C at 3°C/min, stable hold for 5 mins

  2. Auto seeding stage: Maintain -7°C for 10 mins, built-in auto ice nucleation eliminates manual seeding

  3. Slow dehydration cooling stage: Cool from -7°C to -34°C at constant 0.5°C/min (critical window to avoid intracellular ice crystals)

  4. Deep cooling holding stage: Stay at -34°C for 10 mins to finish full embryo dehydration

  5. Final rapid deep cooling stage: Cool from -34°C to -140°C at 50°C/min

  6. End program automatic holding: Lock target temperature, alarm notification triggered after full cycle finishes

Key principle: The 0.5°C/min slow cooling rate between -7°C and -34°C allows intracellular water to flow out gradually, avoiding sharp ice crystal piercing embryo cells, greatly improving post-thaw survival & conception rate.

Customization Reminder

For swine, deer, and special species embryos, you can adjust cooling rate, holding time, and seeding temperature freely on the touch screen, save unlimited exclusive programs.


4. What Makes Our Embryo-Specific Cooler Better Than General Semen Freezers?

Comparison Item

Our Embryo Programmable Cooling System

Ordinary Semen Programmable Freezer

Placement Mode

Horizontal rack, no embryo sinking

Vertical placement, embryos sink to the straw bottom

Seeding Function

Built-in automatic ice seeding

Requires manual LN2 tweezers seeding

Chamber Temperature Uniformity

360° full surrounding air circulation, zero temperature difference

Single-sided air outlet, uneven cooling

Post-Program Protection

Auto constant temperature hold

Temperature rises rapidly after the cycle ends

Control Terminal

Independent large touch screen, no computer needed

Must connect the external PC for editing

Power Consumption

150W low power

250W+ high energy consumption

Program Storage

Unlimited editable embryo protocols

Limited storage space, mostly semen preset curves

Target Application

Optimized for livestock embryo slow freezing

Designed only for sperm straw cryopreservation

5. Main Application Scenarios

5.1 Commercial Livestock Embryo Transfer Labs

For bovine, swine, and sheep embryo breeding stations with daily embryo freezing batches, stable, consistent freezing results guarantee high embryo survival and a stable customer conception rate.

5.2 University & Animal Genetic Research Institutes

Complete real-time temperature curve recording meets academic research data archiving requirements; unlimited customized cooling curves fit various experimental embryo protocols.

5.3 Small Independent Embryo Service Teams

Ultra-low 150W power, no pressurized LN2 tank demand, compact footprint, and simple touch operation perfectly match small-scale labs with limited budget & space.

5.4 Germplasm Resource Preservation Banks

Long-term stable control system, automatic data storage, and low failure rate support year-round continuous embryo cryopreservation work.


6. Frequently Asked Questions

Q1: Can this machine replace imported embryo programmable freezers?

A: Yes. It covers all core embryo freezing functions, including auto-seeding, horizontal placement, curve recording, and post-cycle temperature holding, with a more cost-effective price and simpler operation.

Q2: Does it support all livestock embryo species?

A: The temperature range +40°C ~ -160°C and fully adjustable cooling rate support cattle, pig, goat, sheep, deer, and other animal embryo cryopreservation; unlimited custom programs for special protocols.

Q3: Is manual ice seeding still required during operation?

A: No, it is equipped with a built-in automatic seeding system, completely canceling manual tweezers seeding operation, reducing human error and labor cost.

Q4: What if I cannot transfer embryo straws into the LN2 tank right after the program finishes?

A: After the full freezing cycle ends, the machine will automatically maintain the set low temperature, preventing embryo damage caused by rapid temperature rebound within several hours.

Q5: Can I export the recorded temperature curves for inspection?

A: All running cooling curves are automatically saved inside the control system, exportable for lab quality management and international germplasm export audit documents.


7. Supporting Matching Lab Equipment

Pair this embryo programmable cooling system to build a full embryo processing lab workflow:

  1. Thermostatic heated embryo observation microscope (38°C stage)

  2. Embryo straw filling & sealing machine

  3. LN2 storage tanks (XT series) for long-term embryo preservation

  4. Portable thermostatic thaw cup for post-thaw embryo recovery

  5. ET series small LN2 transport dewars for embryo cross-regional delivery


Standardized controlled-rate freezing is the core guarantee of high embryo post-thaw viability. Most general semen freezers cannot satisfy the special cryogenic demands of livestock embryos, such as an anti-sinking horizontal structure and automatic ice seeding.


Our dedicated programmable embryo cooling system integrates 16 industry-leading, exclusive advantages, is fully compliant with international IETS embryo slow-freezing standards, and supports the complete standard cooling curve for bovine, swine, sheep, and goat embryos. It reduces lab operational difficulty, lowers the embryo loss rate, and cuts long-term equipment maintenance costs.


If you run an embryo transfer lab, animal genetic research institute, or livestock germplasm preservation center, contact our technical team to get detailed machine datasheets, standard embryo freezing program parameters, and bundled lab equipment quotations. We provide full one-stop embryo cryopreservation lab supporting equipment solutions.

 
 
 

Comments


Want to get the latest updates about Heyi Biotech liquid nitrogen container? Follow us.

  • Whatsapp
  • Whatsapp
  • Instagram
  • Youtube
  • Linkedin
  • Facebook
  • skype

©2021 by HeyiLabs. @No.196 Miandong Road, Yanjin, Xinxiang, China 453200

bottom of page