LPT Series Low-Pressure Liquid Nitrogen Tank – All-In-One Storage, Transport & LN2 Dispensing Solution
- Heyi Biotech

- 7 days ago
- 6 min read
If your lab, livestock breeding station, or industrial workshop frequently refills small semen/embryo dewars, you must have struggled with messy manual LN2 pouring, unstable high-pressure tanks, or frequent gas supplier deliveries. Conventional high-pressure LN2 vessels carry safety risks and complex operation, while small portable dewars can’t meet centralized liquid nitrogen supply demands.
Our exclusive LPT series low-pressure liquid nitrogen tank solves all these pain points perfectly. Designed with working pressure below 1 bar, covering a full capacity range from 5L to 2000L, it integrates three core functions: liquid nitrogen storage, short-distance transfer, and automatic LN2 dispensing to all types of small cryogenic containers.
This guide covers core product advantages, standardized operation workflow, industry application scenarios, and comparison with ordinary cryogenic tanks to help you pick the right LPT model for your facility.
Core Technical Specs of LPT Series Low-Pressure LN2 Tank
Full capacity lineup: 5L / 15L / 30L / 50L / 100L / 150L / 240L / 300L / 400L / 500L / 600L / 800L / 1000L / 2000L, custom volume available
Safe low working pressure: Max operating pressure less than 1 bar, far lower than standard pressurized microbulk tanks
Three-in-one core function: LN2 storage, on-site transport, automatic liquid nitrogen dispensing to small dewars
Double-layer high vacuum multi-layer insulation, ultra-low daily evaporation loss
Complete valve assembly: self-pressurizing valve, liquid outlet, vent valve, pressure gauge, liquid level indicator
Optional mobile casters for small & medium models, fixed base for large 1000/2000L stationary tanks
304 stainless steel inner tank, carbon steel outer shell, corrosion-resistant & long service life

8 Unmatched Advantages of LPT Low-Pressure Liquid Nitrogen Tank
1. Ultra-Safe Working Pressure (<1 Bar)
Compared with high-pressure cryogenic tanks (3–8 bar or even higher), the LPT series operates at pressures below 1 bar. No dangerous high-pressure accumulation during vaporization, greatly reducing explosion & leakage risks for daily lab and farm operation, fully compliant with global cryogenic safety standards.
2. Three-In-One Integrated Function (Store + Transport + Dispense)
No separate storage tank + transfer cart + filling device required. One single LPT tank completes:
Long-term liquid nitrogen storage
Short-distance on-site transport between workshops/barns
Automatic LN2 refilling to small semen dewars, embryo dry shippers, and lab cryo containers
Greatly reduce the investment in extra equipment and save lab floor space.
3. Full Capacity Range 5L–2000L For All Scales
Mini 5–50L portable models for small breeding labs & university research rooms; medium 100–500L for mid-size AI stations; large 1000/2000L stationary tanks for gas distributors & large-scale embryo transfer centers. One product line covers all customer demands.
4. Automatic Self-Pressurization For Effortless LN2 Dispensing
Built-in pressure boosting system generates tiny internal pressure by slight natural vaporization, pushing liquid nitrogen out steadily without external pumps. Operators can refill multiple small dewars continuously with one-touch valve control, no manual pouring.
5. Ultra-Low Evaporation Loss, Cut LN2 Procurement Cost
Adopts advanced multi-layer vacuum super insulation + perlite interlayer filling. Minimal heat ingress slows LN2 boil-off drastically, extending refill cycles and lowering your monthly liquid nitrogen purchasing expense.
6. Simple, Low-Maintenance Valve Assembly
Standardized color-coded valve group with pressure & liquid level real-time display. No complicated mechanical parts. Wear-resistant universal spare parts, no expensive proprietary accessories required for long-term upkeep.
7. Flexible Mobility Design
Small & medium LPT tanks install heavy-duty brake casters, easy to push between processing rooms, semen collection yards, and embryo labs. Large 1000/2000L versions adopt a stable fixed foundation base for permanent central supply stations.
8. Wide Compatibility With All Cryogenic Containers
Liquid outlet matches standard cryogenic transfer hoses, perfectly refills all brands of livestock semen tanks, embryo dry shippers, mini LN2 dewars, and lab cryo vessels, fully compatible with your existing breeding lab equipment lineup.
Standard Operation Workflow – Store, Transfer & Dispense LN2 With LPT Tank
Storage Stage: Deliver bulk liquid nitrogen into the LPT tank via tanker, close all valves for sealed low-temperature storage, and monitor liquid level & pressure regularly.
Short-Distance Transfer: Lock brake casters on small/medium models, push the tank to the target processing area safely.
LN2 Dispensing Stage
Connect the cryo transfer hose between the LPT liquid outlet and the target small dewar filling port
Slightly open the self-pressurization valve to build internal pressure under 1 bar
Turn on the liquid outlet valve, and stable LN2 flows into the target container automatically
Close the liquid valve once full, shut the pressurization valve, and disconnect the hose
Finish operation, vent excess internal gas if pressure rises slightly, keep tank sealed for storage.
LPT Tank VS Conventional High-Pressure Microbulk / Separate Dewar Setup
Comparison Item | Our LPT Low Pressure LN2 Tank (<1bar) | High-Pressure Microbulk Tank (3–8bar) | Multiple Separate Small Dewars |
Max Working Pressure | Below 1 bar ultra-safe | 3–8bar high risk | Atmospheric zero pressure, no dispensing function |
Core Functions | Store + transport + automatic LN2 dispensing | Only storage, an external pump is needed for filling | Only sample storage, no bulk supply |
Capacity Options | 5L–2000L full lineup | 500L+ large volume only | Max 200L single tank |
Safety Risk | Minimal low-pressure hazard | High-pressure explosion risk | Frequent manual pouring splashes |
Equipment Investment | Single tank replaces multiple devices | Extra transfer pump & filling station needed | Purchase dozens of small dewars |
Evaporation Rate | Ultra-low vacuum insulation | Medium boil-off loss | Fast heat ingress, frequent refills |
Mobility | Small models with brake casters | Heavy fixed installation only | Hard to carry large batches |
Maintenance Cost | Simple universal valves, low spare part price | Complex high-pressure fittings, expensive repairs | High cumulative replacement cost |
Main Application Industries & Customer Groups
1. Livestock Artificial Insemination & Embryo Labs
The top match for cattle, swine, sheep, and deer semen/embryo breeding stations. Central LN2 supply refills multiple storage dewars & transport dry shippers daily, eliminating repeated bulk LN2 ordering and manual pouring splashes that damage valuable genetic samples.
2. University & Animal Genetic Research Institutes
Mini 5–50L portable LPT tanks fit small lab spaces, supply stable liquid nitrogen for embryo freezing, sperm testing, and cryogenic material experiments.
3. Regional Industrial Gas Distributors
Large 1000/2000L stationary LPT tanks act as central LN2 buffer stations, distributing liquid nitrogen to downstream farms, clinics, and small factories in batches.
4. Medical & Biopharmaceutical Labs
Low-pressure safe design meets medical cryo storage standards for vaccines, stem cells, and biological specimen preservation.
5. Metal Processing & Material Testing Workshops
Continuous LN2 supply for cryogenic shrink fitting, low-temperature material performance testing
Frequently Asked Questions About LPT Low-Pressure LN2 Tank
Q1: Is a pressure below 1 bar safe for daily lab operation?
A: Absolutely. The LPT series only generates tiny internal pressure from natural LN2 vaporization, equipped with a safety relief vent valve to discharge excess gas automatically. No high-pressure buildup risk, far safer than standard pressurized microbulk tanks.
Q2: Can I use the LPT tank to refill all brands of semen dewars?
A: Yes, standard liquid outlet port supports universal cryogenic transfer hoses, compatible with all livestock LN2 storage tanks and embryo dry shippers on the market.
Q3: What size LPT tank should I choose for a mid-size breeding farm?
A: Farms processing under 5000 straws monthly pick 100–500L wheeled LPT models; large embryo transfer stations or gas suppliers select 1000L/2000L stationary versions.
Q4: Does the tank need an external pump to dispense liquid nitrogen?
A: No built-in or external pump required. The self-pressurization system uses natural LN2 evaporation to create gentle internal pressure for stable liquid outflow, simple and failure-free.
Q5: What supporting breeding equipment matches the LPT tank?
A: Perfectly matched with our full lab lineup: programmable semen coolers, embryo freezing machines, thermostatic thaw cups, heated sperm microscopes, and portable straw printers.
Why Choose Our LPT Series Low-Pressure Liquid Nitrogen Tank
Unique <1 bar ultra-low pressure design for maximum daily operation safety
All-in-one storage, transport, and dispensing function cuts extra equipment budget
Complete 5L–2000 volume options to fit small labs and large gas stations
Self-pressurization, automatic liquid output, no manual messy pouring
Premium multi-layer vacuum insulation reduces liquid nitrogen waste in the long term
Mobile wheeled & fixed base dual designs for different site layouts
Standard universal valve components, low maintenance & spare part cost
Fully compatible with all your existing semen/embryo cryogenic containers
A stable, safe liquid nitrogen supply is the basic guarantee of normal operation for breeding labs, research institutes, and industrial workshops. High-pressure cryogenic tanks bring hidden safety hazards, while scattered small dewars lead to high LN consumption and labor waste.
Our LPT series low-pressure liquid nitrogen tank (working pressure less than 1 bar) integrates storage, short-distance transport, and automatic LN2 dispensing into one unit, covering a full capacity from 5L to 2000L. It lowers your equipment investment, reduces monthly cryogen costs, and eliminates high-pressure safety risks.
If you run an artificial insemination farm, embryo transfer center, research lab, or gas distribution business, contact our technical sales team to get detailed LPT model datasheets, capacity selection recommendations, and customized quotations. We provide one-stop full cryogenic lab equipment matching solutions for livestock genetic processing.




Comments